Practical guide

Averaging Water Results with ND: Preserve Limits and Show Assumptions

Keep ND flags and reporting limits. A fictional worksheet shows how explicit substitutions change a mean and what the arithmetic cannot establish.

English-speaking readers interpreting water reports; LCRI discussion concerns U.S. public water systems. · 7 minute read · Published

On this page

Keep the flag beside the value

An ND result is not a measured zero. Keep the result text, reporting limit, units and sample identifier together before calculating anything. A spreadsheet containing only numbers has already lost information if it turned ND into 0 or deleted those rows.

One historical example is the laboratory legend in the Evian 2025 report: ND is reported when the analyte is not detected at or above the stated reporting limit. That particular convention helps explain the flag; it does not tell a reader how to compute a mean for a different report. [1]

If you only have a minimum and maximum, this worksheet cannot recover the missing sample list. Use the range-versus-mean guide first. Here, the starting material is a complete list of results for one defined calculation.

Check the data and declare the arithmetic model

  1. Choose one analyte and mass basis. Convert compatible units without discarding a result flag. A concentration expressed as nitrogen is not the same mass basis as nitrate.
  2. Confirm which samples belong in the calculation: location, period, method, sample purpose, duplicates and weighting. Four listed rows are not necessarily four independent, equally weighted samples.
  3. Read the actual reporting convention. Keep a missing limit or unclear ND definition unresolved; do not borrow a limit from another sample.
  4. Ask what statistic is wanted. A simple arithmetic mean of selected rows, a compliance statistic and a laboratory estimate are different outputs.
  5. If you show substitutions, name the method and keep the original inputs. Do not overwrite the raw results.

For the fictional exercise below, all four rows are compatible, equally weighted and complete. The numeric values are treated as exact teaching inputs. We deliberately choose a model in which each censored numeric estimate is nonnegative and below its stated limit. This is an arithmetic assumption for illustrating missing inputs. It is not a confidence interval for true water concentrations: sampling, analytical uncertainty, rounding and the actual reporting method can change that interpretation.

Work the four-row fictional example

Fictional inputs: one analyte, same units and equal weights
RowRecorded result (µg/L)Input retained for the model
A1Numeric teaching input: 1
B3Numeric teaching input: 3
CND; limit 2Censored estimate c: 0 ≤ c < 2
DND; limit 1Censored estimate d: 0 ≤ d < 1

On a phone, scroll inside the table to read every column. Keyboard users can focus the table and use the arrow keys.

Every row above is invented for this calculation; none is a test of a home, brand or utility. Under the declared model, the sum is 1 + 3 + c + d. The two numeric inputs contribute 4, while the censored estimates add at least 0 and less than 3.

Conditional sum: 4 ≤ sum < 7 µg/L. Conditional arithmetic mean: 1 ≤ mean < 1.75 µg/L. The denominator is four because this exercise explicitly has four selected, equally weighted rows. These bounds describe possible numerical inputs under the model, not a measured mean or an exposure assessment.

If the actual reporting convention includes equality at the limit, the endpoint notation changes. If negative laboratory estimates, uncertainty, unequal weights or missing results are relevant, this simple model does not establish their bounds.

Compare substitutions without disguising them as measurements

Fictional substitution scenarios for the same four rows
Declared scenarioAssigned C and D (µg/L)Resulting illustrative mean
Zero substitution0 and 0(1 + 3 + 0 + 0) ÷ 4 = 1 µg/L
Half-limit substitution1 and 0.5(1 + 3 + 1 + 0.5) ÷ 4 = 1.375 µg/L
Limit substitution2 and 1(1 + 3 + 2 + 1) ÷ 4 = 1.75 µg/L

On a phone, scroll inside the table to read every column. Keyboard users can focus the table and use the arrow keys.

The three numbers differ because assumptions differ. None is a newly measured result. The last scenario uses the limits themselves; with the strict-below-limit model it sits at the excluded upper endpoint. Label it an endpoint substitution scenario, not an attainable value proven by those ND rows.

Deleting the ND rows produces (1 + 3) ÷ 2 = 2 µg/L. That is the mean of the two retained numeric rows, not the mean of the original four-row dataset. A software function that ignores text can silently make exactly this change.

A chosen method may be required for a named monitoring program or analysis. Follow that actual method rather than selecting the scenario that produces a preferred number. This article supplies no universal zero, half-limit or reporting-limit rule.

Keep gaps and weights visible

With four ND rows sharing limit 2 under the same fictional nonnegative model, the selected-row mean can lie from 0 inclusive to 2 exclusive. There is still no measured mean of zero. If even one ND limit is missing, that row has no upper bound supplied by this worksheet; do not insert the smallest limit from another row.

For unequal declared weights, retain each weight and calculate sum(weight × assigned input) ÷ sum(weights). Do not assume a row representing one sample and a row representing ten samples have equal weight. A report’s annual summary may also select locations or periods differently from your spreadsheet.

The useful conclusion can be “the selected data and reporting method do not supply this mean.” Preserve that answer when comparing reports. A narrow-looking output is not better evidence if its missing inputs were invented.

Save the calculation and check the interpretation

Use the blank censored-result record to keep original flags, row selection, units, assumptions and scenario outputs. The file is an ordinary text download; fill it privately with your own records. Ask the report issuer for the actual method if you need its reported statistic.

Case 1

A spreadsheet ignores the two ND text cells and reports 2 µg/L. Has it calculated the four-row mean?

Show answer and explanation for case 1

No. It calculated the mean of the two numeric rows.

Its denominator is two rather than the defined four selected rows. Keep the censored observations visible and identify any assigned-value method.

Case 2

For the four-row exercise, is 1.375 µg/L a laboratory-measured mean?

Show answer and explanation for case 2

No. It is the half-limit substitution scenario.

The calculation assigns 1 and 0.5 to unmeasured numeric inputs. Those assumptions are disclosed; the original report flags remain ND.

Case 3

An ND row has no reporting limit. Can you copy another row’s limit and call the bound established?

Show answer and explanation for case 3

No. Leave that bound unresolved.

The missing limit and reporting convention are required inputs. A different sample or method can have a different limit.

Sources and further reading

  1. Evian 2025 annual water-quality report: historical laboratory ND legendThis dated report supplies a laboratory ND convention. The conditional bounds and substitution scenarios in this guide are separate fictional arithmetic examples, not an averaging procedure prescribed by the report.