Practical guide
Import UCMR 5 Water Results into Excel: Preserve IDs, Blanks and Rows
Choose a subset that fits before loading UCMR 5 text into Excel. Preserve identifier text, the actual result-sign column, units and below-MRL blanks, then compare the loaded rows with the source. A grouped file can still exceed Excel’s worksheet limit, and a spreadsheet that opens successfully can still change the data’s meaning.
Choose a subset that fits before loading a worksheet
Start on EPA’s UCMR occurrence-data page or the UCMR 5 page. If you only need one system or analyte, the Data Finder offers filters and a selected-data Excel download, limited to one million selected records. Use a focused download rather than opening the nationwide text file as a worksheet. Keep the filters and download date with your workbook.
EPA also provides tab-delimited text files grouped by state or analytical method. “Subset” does not mean “small enough for Excel.” In the final by-state ZIP checked on 11 November 2026, UCMR5_All_MA_WY.txt contains 1,191,331 data rows—1,191,332 worksheet rows including its header. Excel’s worksheet limit is 1,048,576 rows. This file cannot fit in a single worksheet unchanged.
If the selected file exceeds the worksheet limit, choose a smaller source subset or narrow the selected Data Finder download before loading. Do not treat a partially loaded sheet as the complete dataset. Keep the original source file so you can distinguish a source record from an import error.
| Your task | Starting option | Check before loading |
|---|---|---|
| Read one system’s results | Filtered UCMR 5 Data Finder download | Selected PWSID, contaminant, fields and record count |
| Compare a bounded group of systems | Filtered download or verified smaller text subset | Scope and row count fit the intended worksheet |
| Use a grouped by-state text file | Inspect actual member and count first | MA_WY currently exceeds a single worksheet’s row limit |
| Analyse the full national dataset | A method that can handle the complete data outside a single worksheet | Do not claim completeness from a truncated Excel sheet |
On a phone, scroll inside the table. Keyboard users can focus the table region and use the arrow keys.
Preview the delimiter, actual header and units
For a text subset that fits, EPA’s January 2025 Excel instructions use a blank workbook: Data → From Text/CSV, select the text file, choose Tab as the delimiter, then choose Transform Data. These are documented Excel/Power Query steps; controls can vary with your Excel edition. The Data Finder’s exported workbook is a different starting format and does not require importing a tab-delimited text file.
Check that the preview separates fields into columns rather than putting a whole line in one cell. The UCMR 5 analytical text file has 24 fields. Match the header before assigning types or writing formulas.
The checked file’s header is AnalyticalResultsSign—with an “s” in Results. Table 7 of EPA’s July 2026 Data Summary uses the same spelling. Some EPA web/instruction text uses AnalyticalResultSign without that “s.” Use the header actually present in your file; do not silently rename a column to satisfy a guessed formula.
Also inspect Units. The checked text uses µg/L with a micro sign. Its micro-sign byte is 0xB5 and the sampled text round-trips correctly through Windows-1252; treating those bytes as UTF-8 produces a decoding error or replacement character. If your preview shows “�g/L,” check the file-origin/encoding setting and the raw source before continuing. This is a check of this download, not a universal encoding rule for every EPA file.
Preserve identifiers as text; assign dates and numbers deliberately
Identifiers are labels, not quantities. In Transform Data, EPA instructs removing the automatically added Changed Type step so the columns return to text, then deliberately typing CollectionDate as Date and MRL and AnalyticalResultValue as Decimal Number. Keep PWSID, FacilityID, SamplePointID, SampleID and event codes as text.
The ZIP-code companion file contains a real public example: PWSID 010106001 is paired with ZIPCODE 06338. Both leading zeros are part of the source text. Verify the exact strings against the source, rather than accepting a workbook display that shortened them. Preserve ZIPCODE as text when importing that separate file too.
Use the source’s US month/day/year date order. For example, 1/2/2025 is 2 January 2025 in CollectionDate, not 1 February. Confirm a known source date after conversion. Keep the original text file for checking a type or locale mistake.
| Field | Type to preserve or assign | What to verify |
|---|---|---|
| PWSID, FacilityID, SamplePointID, SampleID | Text | Exact identifier characters, including leading zeros |
| SampleEventCode, MethodID, Contaminant, Units | Text | Codes and analyte/unit spelling stay attached to each row |
| CollectionDate | Date using the source’s month/day/year order | 1/2/2025 becomes 2 January 2025 |
| MRL, AnalyticalResultValue | Decimal Number | Below-MRL result values remain null, not zero |
| AnalyticalResultsSign | Text | The actual < or = marker is retained |
| ZIPCODE in the companion file | Text | 06338 stays 06338; ZIP service area is not a household sample location |
On a phone, scroll inside the table. Keyboard users can focus the table region and use the arrow keys.
Keep the result sign, blank value and MRL together
Do not delete AnalyticalResultsSign or MRL after importing a numeric value column. In the analytical text file, “<” indicates a result below the UCMR MRL. The corresponding AnalyticalResultValue is blank or null. “=” accompanies a reported numeric value at or above that level. Keep Units and MethodID with the pair.
A blanket “replace null with 0” step changes the meaning of the results. A below-MRL sample is not measured zero. Also, not every blank column has that meaning: EPA defines AssociatedFacilityID, AssociatedSamplePointID and UCMR1SampleType as null for UCMR 5. Read a blank in its own field’s context.
| Fictional row | MRL and units | Sign / value | Correct interpretation |
|---|---|---|---|
| Sample A, PFOA | 0.004 µg/L | < / null | Result below MRL; exact concentration not reported |
| Sample B, PFOA | 0.004 µg/L | = / 0.006 | Reported value 0.006 µg/L; retain its sample identity |
| No matching Sample C row | Not established | No row found | Search/filter result, not a below-MRL measurement |
On a phone, scroll inside the table. Keyboard users can focus the table region and use the arrow keys.
These three rows are original fictional examples. Sample B is not a NYC result and is not a compliance finding. No underlying concentration has been assigned to Sample A.
Load the bounded data, then reconcile it with the source
After the preview, types and subset size are correct, EPA’s text-import instructions use Home → Close & Load. Save the workbook with its source filename, download date and filter scope. Then verify the imported result, not merely whether Excel opened a sheet.
- Compare the loaded record count with the selected source count. Include the header when checking the worksheet’s capacity; exclude it when counting data records.
- Compare a leading-zero identifier, a known date and the Units field with the source.
- Inspect at least one below-MRL row. The sign, MRL and blank numeric value must all still be present.
- For any numeric result used in a calculation, verify its system, facility, sample point, date, sample ID, analyte and method.
- Check whether filters exclude records. Label the workbook as a subset when it is one.
- Keep the original source. Re-import from it when a type, encoding or truncation problem is found; do not patch unknown source values from memory.
- Scope: choose a filtered or verified smaller file.
- Preview: inspect Tab columns, actual headers and unit characters.
- Type: preserve IDs and flags; deliberately convert dates/numbers.
- Reconcile: compare row count and exact source records before analysis.
Work through two fictional import errors
These original fictional cases illustrate checks after import.
Case 1
A fictional import loses the initial zero from a PWSID and changes a below-MRL value from null to 0. The row count still matches. Has the import passed?
Show answer and explanation for case 1
No. The record count passed, but identity and result meaning did not.
Return to the original source. Preserve the identifier as text before the transformation that strips its characters. Remove the null-to-zero transformation and verify sign <, the retained MRL/units and a null result value. A matching row count alone cannot prove a faithful import.
Case 2
A fictional worksheet opens a grouped text subset but warns that the query has more data than will fit. Can you analyse it as the complete selected group?
Show answer and explanation for case 2
No. Choose a bounded subset or a suitable complete-data method, then reconcile the record count.
The source grouping is not proof that a single worksheet can hold it. Keep the warning and source row count with the decision. Do not call the sheet complete, drop records silently or use its partial count as a public-system statistic.
Distinguish missing records from limits and companion files
If a system or sample cannot be found, first clear unintended filters and check the exact PWSID, contaminant and file scope. Do not infer “not detected” from an empty search. The final dataset also should not be described with an old “results will arrive next quarter” assumption simply because that language appeared in January 2025 instructions.
UCMR5_ZIPCodes lists areas served by a system. UCMR5_AddtlDataElem contains other data elements; it is not another copy of every contaminant result. If combining files, use the identifiers appropriate to their level—system, facility, sample point or event—and retain the source fields. A system’s served ZIP does not show where an individual contaminant sample was taken.
Use the finished workbook for the question it can answer
A successful import preserves the source’s rows, identities, units, signs and missing-value meanings. It does not turn UCMR data into a household test, reconstruct unreported concentrations or determine PFAS regulatory compliance. EPA explicitly distinguishes UCMR 5 results from compliance determinations.
For an annual report that seems to disagree with the EPA file, use the cross-report PFOA comparison. For what a laboratory’s undetected result means, use the ND guide.
The official file, selected instructions and result definitions were checked on 11 November 2026. The menu steps follow EPA’s January 2025 instructions; the file-size and header checks use the final dataset available in 2026. Repeat these checks on the file you actually download.
Sources: [4].
Sources and further reading
- EPA: Occurrence Data for the Unregulated Contaminant Monitoring RuleCurrent UCMR 5 file options and final August 2026 release; observed links to grouped text ZIPs and Excel instructions.
- EPA: Instructions for Accessing UCMR Results, January 2025Pages 4–7 document text import, type selection, worksheet row limit, filters and companion-file interpretation. Historical pending-reporting wording is not adopted as current final-dataset status.
- EPA: UCMR 5 Data Summary, July 2026Pages 15–17 and Tables 6–8 define text-file identities, actual AnalyticalResultsSign spelling, null values and ZIP fields.
- EPA: Fifth Unregulated Contaminant Monitoring RuleSelected Data Finder download limit, units, below-MRL values and the distinction between UCMR results and regulatory compliance.
- EPA: UCMR 5 occurrence data by state (ZIP)Actual file check: MA_WY member has 1,191,331 data rows and 24 columns; unit bytes and the public leading-zero identifier/ZIP example were checked against the downloaded source.