Practical guide

PFOA Detected in a Water Report but Not in UCMR 5: Compare the Records

A detected value in an annual water report can coexist with a below-MRL UCMR 5 result. Compare the sampling program, location, date, method, units and reporting limit before deciding what differs. A real dated NYC example shows why a blank UCMR value is neither zero nor the annual-report concentration.

Readers comparing US utility reports with EPA’s UCMR 5 data · 7 minute read · Published

Start with the two programs, not just the chemical name

A number in an annual drinking-water report and a result in EPA’s Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) data can both be valid without describing the same sample. An annual report can summarize several sampling programs. UCMR 5 has its own sampling locations, dates, methods and minimum reporting levels.

Keep both original documents open. Write down the water system, contaminant, reporting year and the specific note attached to the result. “PFOA” appearing in both places is a starting point for comparison, not evidence that every other field matches.

EPA released the final UCMR 5 dataset in August 2026 after monitoring during 2023–2025. Its samples concern participating public systems and entry points to distribution. A utility-wide or entry-point record does not describe a sample collected from your kitchen tap.

Sources: [1], [2].

Read an actual dated example: NYC’s 2025 report

New York City’s 2025 Drinking Water Supply and Quality Report lists PFOA in ng/L, with five samples and a range of ND–2.7. Footnote 19 explains the important detail: PFOA was detected during annual sampling on 8 January 2025 at site 1SCL1, Van Cortlandt Village, ZIP Code 10468; it was not detected during quarterly UCMR 5 monitoring.

The final EPA data contain PFOA records for the NYC system, PWSID NY7003493. One Croton entry-point record has SamplePointID EP1SCL1 and collection date 2 January 2025. Its minimum reporting level is 0.004 µg/L, its result sign is “<”, and its numeric result field is blank. The method is EPA 533.

The dates are six days apart. The annual report uses a site label and footnote; the EPA file uses an entry-point identifier and sample record. Keep those identifiers exactly as published. Do not quietly rewrite them to claim a single physical sample.

Sources: [3], [4].

Historical annual result and a separate UCMR 5 record
FieldNYC annual-report evidenceEPA UCMR 5 evidence
System/document2025 NYC annual reportNY7003493, NEW YORK CITY SYSTEM
ProgramAnnual sampling, footnote 19UCMR 5 assessment monitoring
Location as published1SCL1, Van Cortlandt VillageEP1SCL1, Croton distribution entry point
Collection date8 January 20252 January 2025
PFOA resultAnnual-report detected value: 2.7 ng/LSign <; numeric value blank; MRL 0.004 µg/L
Method/sample identityNot established by this footnote aloneEPA 533; SampleID 380-128435-1

On a phone, scroll inside the table. Keyboard users can focus the table region and use the arrow keys.

This is a historical 2025 example. It illustrates document comparison and is not a statement about today’s tap water. In the NYC PDF, the PFOA row is on printed page 13 and footnote 19 on printed page 16; PDF viewer page numbers are 15 and 18.

Convert units, but keep the reporting boundary attached

For water concentrations in these units, 1 µg/L equals 1,000 ng/L. Convert the result and its limit into the same unit before comparing:

  • 2.7 ng/L ÷ 1,000 = 0.0027 µg/L.
  • 0.004 µg/L × 1,000 = 4 ng/L.
  • Therefore 2.7 ng/L is numerically below a 4 ng/L reporting boundary.

Sources: [1], [2].

That arithmetic shows why a detected value from one program can be compatible with a different program’s below-MRL category. It does not show that the UCMR sample contained exactly 2.7 ng/L, that the annual sample used the UCMR reporting boundary, or that the reporting boundary caused the difference between the two actual samples. The annual footnote does not supply every laboratory detail needed for those claims.

EPA’s UCMR minimum reporting level is based on laboratory reporting capability. It is not a personal health threshold. A number’s position relative to an MRL does not, by itself, determine compliance with a drinking-water regulation.

Sources: [1], [2].

Match the system, point and date before comparing values

Use the identifiers to narrow the official dataset, then inspect the full relevant row. A useful comparison order is:

  1. Match the public water system by PWSID and confirm its name. Similar supplier names are insufficient.
  2. Match the contaminant exactly. PFOA and PFOS are different analytes.
  3. Read FacilityID, SamplePointID and the stated point type. Preserve a utility’s separate site label instead of guessing its mapping.
  4. Compare CollectionDate and SampleID. An annual reporting year is not a sample date; SampleEventCode is not a substitute for the actual date.
  5. Keep MethodID, Units, MRL, AnalyticalResultsSign and AnalyticalResultValue together.
  6. Read the annual-report footnote or laboratory qualifier. Record which fields remain unavailable.

Sources: [2], [4].

For the Croton PFOA records in the checked final file, the four collection dates are 25 October 2023, 11 September 2024, 6 November 2024 and 2 January 2025. These are the actual dates attached to the records; do not generate an evenly spaced calendar from the phrase “quarterly monitoring.”

Sources: [4].

A comparison that keeps the source visible
  1. Identify: system, contaminant and program.
  2. Match: published point label, date and sample ID.
  3. Normalize: units while preserving the sign and limit.
  4. Resolve: state what agrees and which differences remain unexplained.

Keep the UCMR numeric blank unresolved

In the UCMR 5 text results, AnalyticalResultsSign tells you whether the result is below the MRL (“<”) or is a reported numeric value at or above it (“=”). A blank or null AnalyticalResultValue represents a result below the MRL. Do not convert that blank into zero, 2.7 ng/L, half the MRL or the MRL itself.

A missing row is a different situation. If no matching sample record is present after your filters, you have not found that record; you have not found a below-MRL result. Review the system, contaminant, collection date and dataset scope before deciding why it is absent.

Sources: [1], [2].

If you need averages or a legal interpretation, look for the method and full applicable data. This guide does not supply a replacement rule for censored values. For the basic result meaning, see ND and laboratory reporting limits.

Try two fictional comparison checks

These cases are original teaching examples, not additional tests of New York City or another utility.

Case 1

A fictional annual report shows PFOA at 3 ng/L on 10 March. A UCMR-style record at a related point on 3 March has sign <, a blank value and MRL 0.004 µg/L. Can you call the two reports contradictory?

Show answer and explanation for case 1

No. Normalize the units, then retain the different dates and unresolved sample identity.

The boundary is 4 ng/L, so 3 ng/L is below it numerically. The samples were collected on different dates. A different reporting boundary is a plausible compatibility explanation, not proof of the underlying UCMR concentration or cause. Neither zero nor 3 ng/L may be inserted into its blank value.

Case 2

A fictional spreadsheet contains no PFOA rows after you select a supplier name. Can you write “PFOA was not detected” for that supplier?

Show answer and explanation for case 2

No. No matching row and a documented below-MRL result are different findings.

Check the PWSID, filter selections, analyte and dataset scope. A valid below-MRL claim requires the actual record with its result sign, MRL and units. Keep “matching record not found” as the result until you establish what the source contains.

Ask for the missing detail, and separate current notices

When the two documents cannot be fully matched, a precise question is more useful than “Which report is wrong?” For example: “Which site mapping, method and reporting limit apply to annual-report footnote 19, and how does that annual program differ from UCMR SampleID 380-128435-1?” Keep the sources and reported dates with the question.

The NYC sources already identify an annual-versus-quarterly program difference and different dates. That settles the claim that these are automatically the same sample. It does not explain every difference between them or authorize filling an unreported concentration.

EPA explicitly says UCMR 5 results do not indicate PFAS maximum contaminant level compliance or noncompliance. Consult the supplier’s current notices and the applicable drinking-water authority for a current regulatory or household decision. An old annual-report violation column is not a shortcut to today’s status.

Sources: [1], [3].

Finish with a comparison you can check

Your finished comparison should name both sources, the contaminant, system and point, actual dates, common units, result signs and reporting boundaries. State whether the records are the same sample, different samples or not yet fully matched. Separate the numeric calculation from an explanation that still needs evidence.

To work directly with the EPA text data, use the UCMR 5 import guide. To identify the general annual-report fields first, use the Consumer Confidence Report guide.

EPA’s final data and the dated NYC report example were checked on 11 November 2026. Use the original report’s footnotes and the current dataset when repeating the comparison.

Sources and further reading

  1. EPA: Fifth Unregulated Contaminant Monitoring RuleFinal August 2026 dataset, units, reporting levels, result fields, sample scope and distinction from PFAS compliance.
  2. EPA: UCMR 5 Data Summary, July 2026Pages 6, 11–12 and 14–17 explain MRLs, comparison limits, and sample/result fields; Tables 6–7 define identifiers and blank results.
  3. NYC: 2025 Drinking Water Supply and Quality ReportHistorical example: PFOA row on printed page 13 and footnote 19 on printed page 16. Annual detection is dated 8 January 2025; do not treat it as a current household result.
  4. EPA: UCMR 5 occurrence data by state (ZIP)Checked final UCMR5_All_MA_WY.txt records for NY7003493 and PFOA, including the Croton entry-point sample dated 2 January 2025. Access the ZIP from EPA’s occurrence-data page if a download link changes.